Last Modified: 11-29-2007 1.6 C
Service Category: Vehicle Interior Section: Supplemental Restraint Systems
Model Year: 2008 Model: Sequoia Doc ID: RM000002O2T00JX
Title: SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DESCRIPTION (2008 Sequoia)

DTC

B1905/74

Short in Front Passenger Side Pretensioner Squib Circuit

DTC

B1906/74

Open in Front Passenger Side Pretensioner Squib Circuit

DTC

B1907/74

Short to GND in Front Passenger Side Pretensioner Squib Circuit

DTC

B1908/74

Short to B+ in Front Passenger Side Pretensioner Squib Circuit

DESCRIPTION

The front pretensioner squib RH circuit consists of the center airbag sensor and the front seat outer belt RH.

This circuit instructs the SRS to deploy when deployment conditions are met.

These DTCs are stored when a malfunction is detected in the front pretensioner squib RH circuit.

DTC Code

Detection Condition

Trouble Area

B1905/74

When one of following conditions is met:

  • The center airbag sensor receives a line short circuit signal 5 times in the front pretensioner squib RH circuit during primary check.
  • Front pretensioner squib RH malfunction
  • Center airbag sensor malfunction
  • No. 2 floor wire
  • Front seat outer belt assembly RH (Front pretensioner squib RH)
  • Center airbag sensor assembly

B1906/74

When one of following conditions is met:

  • The center airbag sensor receives an open circuit signal in the front pretensioner squib RH circuit for 2 seconds.
  • Front pretensioner squib RH malfunction
  • Center airbag sensor malfunction
  • No. 2 floor wire
  • Front seat outer belt assembly RH (Front pretensioner squib RH)
  • Center airbag sensor assembly

B1907/74

When one of following conditions is met:

  • The center airbag sensor receives a short circuit to ground signal in the front pretensioner squib RH circuit for 0.5 seconds.
  • Front pretensioner squib RH malfunction
  • Center airbag sensor malfunction
  • No. 2 floor wire
  • Front seat outer belt assembly RH (Front pretensioner squib RH)
  • Center airbag sensor assembly

B1908/74

When one of following conditions is met:

  • The center airbag sensor receives a short circuit to B+ signal in the front pretensioner squib RH circuit for 0.5 seconds.
  • Front pretensioner squib RH malfunction
  • Center airbag sensor malfunction
  • No. 2 floor wire
  • Front seat outer belt assembly RH (Front pretensioner squib RH)
  • Center airbag sensor assembly

WIRING DIAGRAM



INSPECTION PROCEDURE

HINT:

PROCEDURE

1.

CHECK CONNECTOR

(a) Turn the ignition switch off.

(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

(c) Check that the connector is properly connected to the front seat outer belt RH.

OK:

The connector is properly connected.

HINT:

If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

(d) Disconnect the connector from the front seat outer belt RH.

(e) Check that the No. 2 floor wire connector (on the front seat outer belt RH side) is not damaged.

OK:

The lock button is not disengaged, or the claw of the lock is not deformed or damaged.

OK

2.

CHECK FRONT SEAT OUTER BELT RH (FRONT PRETENSIONER SQUIB RH)


(a) Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.

CAUTION:

Never connect the tester to the front seat outer belt RH (front pretensioner squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

NOTICE:

  • Do not forcibly insert SST into the terminals of the connector when connecting SST.
  • Insert SST straight into the terminals of the connector.

SST: 09843-18061

(b) Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

(c) Turn the ignition switch to ON, and wait for at least 60 seconds.

(d) Clear the DTCs SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DTC CHECK / CLEAR (2008 Sequoia) .

(e) Turn the ignition switch off.

(f) Turn the ignition switch to ON, and wait for at least 60 seconds.

(g) Check for DTCs SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DTC CHECK / CLEAR (2008 Sequoia) .

OK:

DTC B1905, B1906, B1907, B1908 or 74 is not output.

HINT:

Codes other than DTC B1905, B1906, B1907, B1908 and 74 may be output at this time, but they are not related to this check.

OK

3.

CHECK CONNECTOR

(a) Turn the ignition switch off.

(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

(c) Disconnect SST from connector C.

(d) Check that the connector is properly connected to the center airbag sensor assembly.

OK:

The connector is properly connected.

HINT:

If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

(e) Disconnect the connector from the center airbag sensor assembly.

(f) Check that the terminal of the connector is not damaged.

OK:

The terminal is not deformed or damaged.

(g) Check that the short spring for the No. 2 floor wire connector with the activation prevention mechanism is not deformed or damaged.

OK:

The short spring is not deformed or damaged.

OK

4.

CHECK NO. 2 FLOOR WIRE (FRONT PRETENSIONER SQUIB RH CIRCUIT)


(a) Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

(b) Turn the ignition switch to ON.

(c) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Switch Condition

Specified Condition

P8-1 (R+) - Body ground

Ignition switch ON

Below 1 V

P8-2 (R-) - Body ground

Ignition switch ON

Below 1 V

(d) Turn the ignition switch off.

(e) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

(f) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

P8-1 (R+) - P8-2 (R-)

Always

Below 1 Ω

(g) Release the activation prevention mechanism built into connector B SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DIAGNOSIS SYSTEM (2008 Sequoia) .

(h) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

P8-1 (R+) - P8-2 (R-)

Always

1 MΩ or higher

P8-1 (R+) - Body ground

Always

1 MΩ or higher

P8-2 (R-) - Body ground

Always

1 MΩ or higher

OK

5.

CHECK CENTER AIRBAG SENSOR


(a) Restore the released activation prevention mechanism of connector B to the original condition.

(b) Connect the connectors to the front seat outer belt RH and the center airbag sensor.

(c) Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

(d) Turn the ignition switch to ON, and wait for at least 60 seconds.

(e) Clear the DTCs stored in the memory SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DTC CHECK / CLEAR (2008 Sequoia) .

(f) Turn the ignition switch off.

(g) Turn the ignition switch to ON, and wait for at least 60 seconds.

(h) Check the DTCs SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: DTC CHECK / CLEAR (2008 Sequoia) .

OK:

DTC B1905, B1906, B1907, B1908 or 74 is not output.

HINT:

Codes other than DTC B1905, B1906, B1907, B1908 and 74 may be output at this time, but they are not related to this check.

OK